Product Details:
|
Name: | CT Connection Amr AMI Electric Meter Multifunction Power Meter 3×57.7 100V 20 80A | Technical Standards: | IEC62052-11,IEC 62053-21,IEC 62053-22, IEC62053-23 |
---|---|---|---|
Protocol: | IEC62056-21, IEC62056-42, IEC62056-46, IEC62056-53, IEC62056-61,IEC62056-62 | Reference Voltage: | 3×57.7/100V;3×120/208V;3×220/380V |
Current: | CT Connection: 1.5(6)A,5(6)A,5(10)A, Direct Connection:10(40)A,10(60)A,20(80)A,10(100A | Reference Frequency: | 50/60Hz |
Power Consumption: | <1.5W,6VA(For Each Phase) | ||
High Light: | RISESUN CT connection AMI Meter,Iec 62053 22 AMI Electric Meter,RISESUN Multifunction Power Meter |
Multifunction Electronic Energy Meter with LCD display
General Introduction
Multifunction Electronic Energy Meter with LCD display can measure the import and the export active energy, the inductive and the capacitive reactive energy, and is with TOU function. It has the anti-tamper function, it will alarm in time of detected tamper events, such as current reversal, voltage phase sequence reverse, meter cover open and terminal cover open, bypass, etc.
Technical specifications
Items | contents |
Standards | IEC62052-11; IEC62053-21; IEC62053-22; IEC62053-23; |
Accuracy | Active:Class 0.2S or Class 0.5S or Class 1.0; Reactive:Class 2 |
Protocol | IEC62056-21;IEC62056-42;IEC62056-46;IEC62056-53;IEC62056-61;IEC62056-62 |
Reference voltage | 3×57.7/100V;3×120/208V;3×220/380V |
Current |
CT connection:1.5(6)A,5(6)A,5(10)A, Direct connection:10(40)A,10(60)A,20(80)A,10(100)A |
Reference frequency | 50/60Hz |
Power consumption | <1.5W,6VA(For each phase) |
Operation voltage range | 0.8Un~1.2Un |
Limited operation voltage range | 0.7Un~1.3Un |
Operation temperature range | -25℃~ +60℃ |
Limited operation temperature range | -40℃~ +70℃ |
RTC deviation | ≤0.5s/d |
Life time | 15 years |
Size | 290mm(L)×170mm(W)×85mm(H) |
Net weight | About 2.8kg |
Main functions
1. Metering and measurements: It can measure voltage, current, active power, reactive power, apparent power, power factor, etc. It can measure the import and export active maximum demand, and four quadrant reactive maximum demand. It is with high accuracy. Class 0.2S, Class 0.5S or Class 1.0 for kWh are available.
2. Display and indication: It adopts a large screen LCD with abundant graphics and hint text. The displayed contents can be scrolled automatically or by button, and the displayed items can be configured as per the requirements. It is with backlight. Meter can be read during power outage.
3. TOU: 4 tariffs; Built-in 2 sets of time zone tables and 2 sets of daily period tables, which can be configured as per the requirements. Moreover, the switching time for both 2 sets of time zone tables and 2 sets of daily period tables can be set and achieve the mutual switching. It can set 14 day period tables and 14 week tables and 100 public holidays.
4. Load profile: It can record the data of multi-channel load profile.
5. Anti-Tamper: The meter will alarm in time of detected the tamper events, such as current reversal, voltage phase sequence reverse, meter cover open and terminal cover open, bypass, etc.
6. Event logs: It can separately record latest 10 times events, such as power outage, programming, time correction, meter cover open, disconnection and reconnection, reset of events, reset of meter, etc.
7. Communication interface: The meter has one optical port, one RS485 and one RS232. These three interfaces are independent with each other.
Honorary Qualification
Each of honors accompanies each step of the growth of Risesun, but Risesun's people have always believed that honor only belongs to yesterday, and does not represent today and tomorrow, and all that we have now is to give us a reason to climb higher. For better tomorrow, Risesun's people work hard as always.
System advantages
1.Diversity of management:
Managing range covers the different types of energy consumed objects, such as Substations, Users with special transformer, Distribution transformers, Residential Users, etc. It can configure the relevant managing function according to the type of object.
2.Flexibility of configuration:
2.1 Function modularization: It can customize the equipment and separately deploy the modules according to the size of the management scale.
2.2 The function is hierarchically designed, which can guarantee clear logic, convenient maintenance and the stable operation.
3.Compatibility of equipments:
The users can choose the appropriate mode of network (such as GPRS, PLC, WSN or 485), the collection equipments (such as various energy meters or concentrators) and the operation protocol of equipments according to their own situation. The system can provide support or expansion.
Contact Person: admin
Tel: +8613714190315