Product Details:
|
Name: | GPRS PLC LORA Kwh Meter Digital 3 Phase Dlms Smart Meter Class 0.5 S Accuracy | Standards: | IEC62052-11; IEC62053-21;IEC62053-22; IEC62053-23;IEC62056-21 Protocol IEC62056-21;IEC62056-42;IEC62056-46;IEC62056-53;IEC62056-61;IEC62056-62; |
---|---|---|---|
Reference Voltage: | 3×57.7/100V;3×120/208V;3×220/380V;3×230/400V | Reference Frequency: | 50/60 Hz |
Power Consumption: | <1.5W, 6VA(per Phase) | RTC Deviation: | ≤0.5s/d |
Net Weight: | About 2.8kg | ||
High Light: | Three Phase Dlms Smart Meter,risesun digital kwh meter 3 phase,risesun 3ph smart meter dlms protocol |
Three Phase Smart Meter with Communication as per DLMS
General introduction
Three Phase Smart Meter with Communication as per DLMS is with wide voltage range and four tariffs, and used for measuring the import and export active and reactive energy. It also supports optical port and Plug& Play module such as GPRS, RF, PLC, ZigBee, etc. The meter includes metering, RTC, load control unit and other component.
Main functions
Technical specifications
Items | contents |
Standards | IEC62052-11; IEC62053-21;IEC62053-22; IEC62053-23;IEC62056-21 |
Protocol | IEC62056-21;IEC62056-42;IEC62056-46;IEC62056-53;IEC62056-61;IEC62056-62; |
Accuracy | Active: Class 0.2S,0.5S or Class 1 Reactive: Class2 |
Reference voltage | 3×57.7/100V;3×120/208V;3×220/380V;3×230/400V |
Current | Current transformer connection:1.5(6)A,5(6)A,5(10)A, Direct connection: 10(40)A,10(60)A,20(80)A,10(100)A |
Reference frequency | 50/60 Hz |
Power consumption | <1.5W, 6VA(per phase) |
Operation voltage range | 0.8Un~1.2Un |
Limited operation voltage range | 0.7Un~1.3Un |
Operation temperature | -25℃~ +60℃ |
Limited operation temperature range | -40℃~ +70℃ |
RTC deviation | ≤0.5s/d |
Size | 290mm(L)×170mm(W)×85mm(H) |
Life time | 15 years |
Net weight | About 2.8kg |
Q & A
Q: What kind of timing functions do smart energy meter have? How about the accuracy?
A: Smart energy meter adopts built-in hardware clock circuit with temperature companion function, which has automation conversion function among calendar, time and leap year; the output frequency of internal clock terminals of energy meter is 1 Hz. Within the temperature range of 25~+60℃, the clock accuracy is ≤±1s/d; Under the reference temperature (23℃), the clock accuracy is ≤±0.5s/d. It adopts green environmental protection lithium battery as standby power supply, and the capacity of battery is more than 1.2Ah. During the life cycle of energy meter, the battery needn’t to be changed, and it can make internal clock work correctly for more than 5 years after power outage.
Contact Person: admin
Tel: +8613714190315