Product Details:
|
Name: | Step Tariffs AMI Smart Meter 3 Phase Electronic Energy Meter 3x120 208V | Standards: | IEC62052-11,IEC62053-21,IEC62053-23,IEC62055-31,IEC62055-41, IEC62055-51 |
---|---|---|---|
Protocol: | IEC62056-21 | Current: | 5(80)A 10(100)A |
Power Consumption: | <1.5W,6VA | Operation Voltage Range: | 0.8Un~1.2Un |
Operation Temperature: | -25℃~ +60℃ | RTC Deviation: | ≤0.5s/d |
Life Time: | 15 Years | ||
High Light: | 3x120 208V Step Tariffs AMI Smart Meter,3x120 208V 3 phase energy metre,3x120 208V AMI 3 Phase Electronic Energy Meter |
Step tariffs Three Phase STS Keypad Prepaid Meter with interchangeable Module
General introduction
1) The meter adopts STS standard encryption algorithm to exchange the information based on TOKEN.
2) It has the functions such as metering, monitoring, alarm, display, communication and load control, etc.
3)Step tariffs Three Phase STS Keypad Prepaid Meter with interchangeable Module is featured with strong compatibility,easy operation, high metering accuracy, high level security, etc.
4) Step tariffs.
5) Anti-tamper: Detecting current reverse, magnetic influence, phase bypass, meter cover open, terminal cover open etc, at the same time the meter can disconnect power supply when the tampers occur which are configured.
Main functions
Support UIU
TOU
Four tariffs; support public holidays and weekends;two sets of time zone tables; two sets of time period tables.
Friendly power supply management
Support emergency credit
Events logs
Detecting and recording events such as current reverse, magnetic influence, phase bypass, meter cover open, terminal cover open, overvoltage, under voltage, etc.
Audio and visual alarm
Current reverse, magnetic influence, phase bypass, meter cover open, terminal cover open can be alarmed which are configured.
Disconnection /reconnection
Detecting the customer's load status, it can alarm or disconnect the power supply when overload happens.
Communication interface
Optical port and RS485 interface are available; PLC, RF, GPRS,3G or twist-wire interface is optional.
UIU interface
PLC, RF or twist-wire is optional.
Technical specifications
Items |
contents |
Standards |
IEC62052-11; IEC62053-21;IEC62053-23; IEC62055-31;IEC62055-41;IEC62055-51; |
Accuracy |
Active:Class 1; Reactive: Class 2 |
Protocol |
IEC62056-21 |
Reference voltage |
3*220/380V 3*230V/400V 3*240/415V 3*120/208V |
Current |
5(80)A,10(100)A |
Reference frequency |
50/60 Hz |
Power consumption |
<1.5W, 6VA |
Operation voltage range |
0.8Un~1.2Un |
Limited operation voltage range |
0.7Un~1.3Un |
Operation temperature |
-25℃~ +60℃ |
Limited operation temperature range |
-40℃~ +70℃ |
RTC deviation |
≤0.5s/d |
Life time |
15 years |
Size |
290mm(L)×170mm(W)×85mm(H) |
Net weight |
About 2.6kg |
Q&A
Q: What are the differences between smart energy meter and ordinary energy meter?
A: (1) Ordinary energy meter only has the energy metering function. While besides the basic function of energy metering, smart energy meter also has other various functions, such as data storage, real time monitoring, automatic control, information exchange, etc. Besides, it is provided with multiple functions, such as forward and reverse measurement, TOU measurement, remote meter reading, remote monitoring and control, electrical parameters measurement, security protection of consumed energy information, event logs, etc.
(2) Compared with previous energy meters, smart energy meter is added many new functions, such as measurement information management, information management of energy consumed, monitoring of energy quantities consumed, etc., which can better provide users with accurate and timely billing function.
(3) It has the bidirectional metering function and supports the distributed energy utilization. In addition to recording the import energy, it also can record the export energy. If the user is self-built with distributed clean energy generation facilities, such as wind energy, solar energy, etc., it can realize to transmit the spare energy to power grid when the generated power cannot be exhausted, thus achieve energy conservation and environmental protection to reduce carbon dioxide emissions, create low carbon life and improve the users' economic benefits.
Q: What kind of error message code prompts do LCD screen of smart energy meter have?
A: When malfunction appears in energy meter, it will display error message codes:
(1) Err-01 Control loop error
(2) Err-02 ESAM error
(3) Err-04 Low battery voltage of clock
(4) Err-08 Clock failure
(5) Err-10 Authentication error
(6) Err-16 Change key error
Contact Person: admin
Tel: +8613714190315