Product Details:
|
Name: | Iec 62053 Part 21 Smart AMI Energy Meter 3 Phase Metre With LCD Display | Standards: | IEC62052-11; IEC62053-21;IEC62053-22; IEC62053-23;IEC62056-21 Protocol IEC62056-21;IEC62056-42;IEC62056-46;IEC62056-53;IEC62056-61;IEC62056-62; |
---|---|---|---|
Accuracy Active: | Class 0.2S,0.5S Or Class 1 Reactive: Class2 | Reference Voltage: | 3×57.7/100V;3×120/208V;3×220/380V;3×230/400V |
Reference Frequency: | 50/60 Hz | Power Consumption: | <1.5W, 6VA(per Phase) |
RTC Deviation: | ≤0.5s/d | ||
High Light: | Iec 62053 Part 21 Smart AMI Energy Meter,Iec 62053 Part 21 Smart Meter Ami,Iec 62053 Part 21 Three Phase AMI Energy Meter |
Three Phase Smart Meter with LCD display
General introductio
Three Phase Smart Meter with LCD display is with wide voltage range and four tariffs, and used for measuring the import and export active and reactive energy. It also supports optical port and Plug& Play module such as GPRS, RF, PLC, ZigBee, etc. The meter includes metering, RTC, load control unit and other component.
Main functions
LCD display
Active, reactive impulse output
Abnormal power consumption alarm
Remote disconnection and reconnection control
One RS485, one RS232 and one optical port, all interfaces are independent
Plug& Play modules (GPRS,3G, RF, PLC etc.)
TOU for import and export active energy, reactive energy and apparent energy
TOU for import and export active M.D., reactive M.D. and apparent M.D. with timestamp
TOU for import and export active cumulative demand, reactive cumulative demand and apparent cumulative demand
TOU for average power factor
TOU for average frequency
Billing (automatically or manual mode)
M.D. reset
Recording Multi-channel load profile
Measuring voltage, current, neutral current, active power, reactive power, apparent power, power factor, phase angle, frequency per phase, etc.
Events logs: power outage, demand reset, under voltage, overvoltage, phase loss, current reverse, voltage phase sequence reverse, voltage unbalance, current unbalance, meter cover open, meter terminal cover open, etc.
Hardware failure alarm
Meter reads when power outage
Power quality monitor: under voltage, overvoltage, phase loss, voltage unbalance, current unbalance, etc.
Anti-tamper: phase bypass, current reverse, voltage phase sequence reverse, meter cover open, meter terminal cover open, etc.
With KEMA Certificate.
Technical specifications
Items | contents |
Standards | IEC62052-11; IEC62053-21;IEC62053-22; IEC62053-23;IEC62056-21 |
Protocol | IEC62056-21;IEC62056-42;IEC62056-46;IEC62056-53;IEC62056-61;IEC62056-62; |
Accuracy | Active: Class 0.2S,0.5S or Class 1 Reactive: Class2 |
Reference voltage | 3×57.7/100V;3×120/208V;3×220/380V;3×230/400V |
Current | Current transformer connection:1.5(6)A,5(6)A,5(10)A, Direct connection: 10(40)A,10(60)A,20(80)A,10(100)A |
Reference frequency | 50/60 Hz |
Power consumption | <1.5W, 6VA(per phase) |
Operation voltage range | 0.8Un~1.2Un |
Limited operation voltage range | 0.7Un~1.3Un |
Operation temperature | -25℃~ +60℃ |
Limited operation temperature range | -40℃~ +70℃ |
RTC deviation | ≤0.5s/d |
Size | 290mm(L)×170mm(W)×85mm(H) |
Life time | 15 years |
Net weight | About 2.8kg |
AMI System Architecture Diagram
Q & A
Q1: What are the differences between smart energy meter and ordinary energy meter?
A1: (1) Ordinary energy meter only has the energy metering function. While besides the basic function of energy metering, smart energy meter also has other various functions, such as data storage, real time monitoring, automatic control, information exchange, etc. Besides, it is provided with multiple functions, such as forward and reverse measurement, TOU measurement, remote meter reading, remote monitoring and control, electrical parameters measurement, security protection of consumed energy information, event logs, etc.
(2) Compared with previous energy meters, smart energy meter is added many new functions, such as measurement information management, information management of energy consumed, monitoring of energy quantities consumed, etc., which can better provide users with accurate and timely billing function.
(3) It has the bidirectional metering function and supports the distributed energy utilization. In addition to recording the import energy, it also can record the export energy. If the user is self-built with distributed clean energy generation facilities, such as wind energy, solar energy, etc., it can realize to transmit the spare energy to power grid when the generated power cannot be exhausted, thus achieve energy conservation and environmental protection to reduce carbon dioxide emissions, create low carbon life and improve the users' economic benefits.
Q2: What kind of timing functions do smart energy meter have? How about the accuracy?
A2: Smart energy meter adopts built-in hardware clock circuit with temperature companion function, which has automation conversion function among calendar, time and leap year; the output frequency of internal clock terminals of energy meter is 1 Hz. Within the temperature range of 25~+60℃, the clock accuracy is ≤±1s/d; Under the reference temperature (23℃), the clock accuracy is ≤±0.5s/d. It adopts green environmental protection lithium battery as standby power supply, and the capacity of battery is more than 1.2Ah. During the life cycle of energy meter, the battery needn’t to be changed, and it can make internal clock work correctly for more than 5 years after power outage.
Contact Person: admin
Tel: +8613714190315