Product Details:
|
Name: | IEC 62056 46 AMI Smart Meter Three Phase Four Wire Energy Meter Multifunction | Technical Standards: | IEC62052-11,IEC 62053-21,IEC 62053-22, IEC62053-23 |
---|---|---|---|
Protocol: | IEC62056-21, IEC62056-42, IEC62056-46, IEC62056-53, IEC62056-61,IEC62056-62 | Operation Voltage Range: | 0.8Un~1.2Un |
Limited Operation Voltage Range: | 0.7Un~1.3Un | RTC Deviation: | ≤0.5s/d |
Life Time: | 15 Years | ||
High Light: | IEC 62056 46 three phase four wire energy meter,three phase four wire energy meter IEC 62056 46,IEC 62056 46 3 phase 4 wire static watt hour meter |
DTZ217 Three Phase Four Wire Multifunction active Electronic Energy Meter
General Introduction
DTZ217 Three Phase Four Wire Mulifunction Electronic active Energy Meter can measure the import and the export active energy, the inductive and the capacitive reactive energy, and is with TOU function. It has the anti-tamper function, it will alarm in time of detected tamper events, such as current reversal, voltage phase sequence reverse, meter cover open and terminal cover open, bypass, etc.
Display and indication adopts a large screen LCD with abundant graphics and hint text. The displayed contents can be scrolled automatically or by button, and the displayed items can be configured as per the requirements. It is with backlight. Meter can be read during power outage.
Technical specifications
Items | contents |
Standards | IEC62052-11; IEC62053-21; IEC62053-22; IEC62053-23; |
Accuracy | Active:Class 0.2S or Class 0.5S or Class 1.0; Reactive:Class 2 |
Protocol | IEC62056-21;IEC62056-42;IEC62056-46;IEC62056-53;IEC62056-61;IEC62056-62 |
Reference voltage | 3×57.7/100V;3×120/208V;3×220/380V |
Current |
CT connection:1.5(6)A,5(6)A,5(10)A, Direct connection:10(40)A,10(60)A,20(80)A,10(100)A |
Reference frequency | 50/60Hz |
Power consumption | <1.5W,6VA(For each phase) |
Operation voltage range | 0.8Un~1.2Un |
Limited operation voltage range | 0.7Un~1.3Un |
Operation temperature range | -25℃~ +60℃ |
Limited operation temperature range | -40℃~ +70℃ |
RTC deviation | ≤0.5s/d |
Life time | 15 years |
Size | 290mm(L)×170mm(W)×85mm(H) |
Net weight | About 2.8kg |
Main functions
1. Metering and measurements: It can measure voltage, current, active power, reactive power, apparent power, power factor, etc. It can measure the import and export active maximum demand, and four quadrant reactive maximum demand. It is with high accuracy. Class 0.2S, Class 0.5S or Class 1.0 for kWh are available.
2. Display and indication: It adopts a large screen LCD with abundant graphics and hint text. The displayed contents can be scrolled automatically or by button, and the displayed items can be configured as per the requirements. It is with backlight. Meter can be read during power outage.
3. TOU: 4 tariffs; Built-in 2 sets of time zone tables and 2 sets of daily period tables, which can be configured as per the requirements. Moreover, the switching time for both 2 sets of time zone tables and 2 sets of daily period tables can be set and achieve the mutual switching. It can set 14 day period tables and 14 week tables and 100 public holidays.
4. Load profile: It can record the data of multi-channel load profile.
5. Anti-Tamper: The meter will alarm in time of detected the tamper events, such as current reversal, voltage phase sequence reverse, meter cover open and terminal cover open, bypass, etc.
6. Event logs: It can separately record latest 10 times events, such as power outage, programming, time correction, meter cover open, disconnection and reconnection, reset of events, reset of meter, etc.
7. Communication interface: The meter has one optical port, one RS485 and one RS232. These three interfaces are independent with each other.
System Main functions
1. Maintenance of system operation; Management of authority; Management of equipment's archives.
2. Collection of equipment's data. The collection plan can be configured. .
3. Electric Data analysis and power grid quality analysis.
4. Comprehensive line loss analysis.
5. Energy measurement equipment monitoring.
6. Remote control (electricity cut-off/switch-on)..
7. Electric data publishing..
8. Connection interface with other system..
AMI System Architecture Diagram
Contact Person: admin
Tel: +8613714190315